CODMAN Disposable Perforator 9mm. Cranial Perforator. Class I

Reason: Expansion of recall of size 14 mm Codman Disposable Perforators for inadequate welds to size 11 mm and 9 mm Codman Disposable Perforators out of an abundance of caution.

Integra LifeSciences Corp. (NeuroSciences) 20250926 Ongoing
Distributed: Worldwide distribution - US Nationwide and the countries of Argentina, Australia, Austria, Bahamas, Barbados, Belgium, Brazil, Canada, Chile, Colombia, Cyprus, Czechia, Ecuador, France, French Guiana, Germany, Greece, India, Ireland, Italy, Japan, Jordan, Korea, Lithuania, Mexico, Morrocco, Netherlands, New Zealand, Palestine, State of, Philippines, Portugal, Puerto Rico, Qatar, Republic of North Macedonia, Saudi Arabia, Singapore, Slovenia, South Africa, Spain, Sri Lanka, Sweden, Switzerland, Taiwan , Thailand, Trinidad and Tobago, Tunisia, Turkey, United Arab Emirates, United Kingdom of Great Britain and Northern Ireland, Vietnam.
CODMAN Disposable Perforator 11mm. Cranial Perforator. Class I

Reason: Expansion of recall of size 14 mm Codman Disposable Perforators for inadequate welds to size 11 mm and 9 mm Codman Disposable Perforators out of an abundance of caution.

Integra LifeSciences Corp. (NeuroSciences) 20250926 Ongoing
Distributed: Worldwide distribution - US Nationwide and the countries of Argentina, Australia, Austria, Bahamas, Barbados, Belgium, Brazil, Canada, Chile, Colombia, Cyprus, Czechia, Ecuador, France, French Guiana, Germany, Greece, India, Ireland, Italy, Japan, Jordan, Korea, Lithuania, Mexico, Morrocco, Netherlands, New Zealand, Palestine, State of, Philippines, Portugal, Puerto Rico, Qatar, Republic of North Macedonia, Saudi Arabia, Singapore, Slovenia, South Africa, Spain, Sri Lanka, Sweden, Switzerland, Taiwan , Thailand, Trinidad and Tobago, Tunisia, Turkey, United Arab Emirates, United Kingdom of Great Britain and Northern Ireland, Vietnam.
Osstem Dental X-Ray System T2Plus. Product Model Numbers T2-C-P and T2-CS-P. Class II

Reason: Osstem Implant Co. Ltd, is voluntarily initiating a medical device correction involving the current labeling for this electronic product may be missing a required Certification Statement under 21 CFR Subchapter J (Radiological Health Regulations). Specifically, the following statement may have been omitted: Certification Statement: This electronic product complies with all applicable performance standards prescribed under 21 CFR Subchapter J, as enforced by the U.S. Food and Drug Administration at the date of manufacturing.

OSSTEM Implant Co., Ltd. 20250826 Ongoing
Distributed: U.S.
Osstem Dental X-Ray System T2. Product Model Numbers T2-C and T2-CS. Class II

Reason: Osstem Implant Co. Ltd, is voluntarily initiating a medical device correction involving the current labeling for this electronic product may be missing a required Certification Statement under 21 CFR Subchapter J (Radiological Health Regulations). Specifically, the following statement may have been omitted: Certification Statement: This electronic product complies with all applicable performance standards prescribed under 21 CFR Subchapter J, as enforced by the U.S. Food and Drug Administration at the date of manufacturing.

OSSTEM Implant Co., Ltd. 20250826 Ongoing
Distributed: U.S.
Osstem Dental X-Ray System T1. Product Model Numbers T1-C and T1-CS. Class II

Reason: Osstem Implant Co. Ltd, is voluntarily initiating a medical device correction involving the current labeling for this electronic product may be missing a required Certification Statement under 21 CFR Subchapter J (Radiological Health Regulations). Specifically, the following statement may have been omitted: Certification Statement: This electronic product complies with all applicable performance standards prescribed under 21 CFR Subchapter J, as enforced by the U.S. Food and Drug Administration at the date of manufacturing.

OSSTEM Implant Co., Ltd. 20250826 Ongoing
Distributed: U.S.
Thermo scientific MAS Omni CARDIO, Liquid Assayed Integrated Cardiac Control, Model/Catalog Number: OCRD-L, OCRD-101, OCRD-202, OCRD-303, OCRD-SP, OCRD-MP, OCRD-UL; Product Description: In Vitro Diagnostic external control Class II

Reason: The firm received complaints from customers reporting vial-to-vial variability when using the control with high sensitivity Troponin I assays. This defect may lead to as delay in patient results for hs Troponin I assays.

Microgenics Corporation 20251001 Ongoing
Distributed: Worldwide - US Nationwide distribution in the states of AL, OK, NH, NY, WI, IL, LA, AR, TX, UT, GA, ID and the countries of MEX, CAN, KOR, MYS, DEU, GBR, BRA, JAP, HKG, NZL, AUS.
Xpert SA Nasal Complete Catalog Number: GXSACOMP-10 UDI-DI code: 07332940000158 Xpert SA Nasal Complete kit; 10 test kit: A collection of reagents and other associated materials intended to be used for the direct qualitative and/or quantitative detection of nucleic acid from methicillin-resistant and methicillin-susceptible Staphylococcus aureus (MRSA/MSSA) bacteria present in a clinical specimen, using a nucleic acid technique Class II

Reason: As a result of Post-Market half-time stability testing, false negative test result was observed for a positive sample type.

Cepheid 20250806 Ongoing
Distributed: U.S. Nationwide distribution including in the states of AK, AL, AR, AZ, CA, CO, CT, DE, FL, GA, IA, ID, IL, IN, KS, KY, LA, MA, MD, ME, MI, MN, MO, MS, MT, NC, NH, NJ, NV, NY, OH, OK, OR, PA, PR, SC, TN, TX, UT, VA, WA, WI, WV, and WY.
Good Neighbor Pharmacy, TRUE METRIX Self Monitoring Blood Glucose Meter. Model/Catalog Number: RE4011-01. Class II

Reason: Manufacturing defect causing LCD display issues with missing or partial segments (ghosting) that can result in misreading glucose values, potentially leading to inappropriate treatment decisions for diabetes management.

Trividia Health, Inc. 20251007 Ongoing
Distributed: US Nationwide distribution in the states of NY, VA, FL, OH, CA, KY, NC.
CellMek SPS Sample Preparation System, REF: C44603. Software versions 2.2.122.0 and prior, and Instructions for Use (IFU) revisions AD and prior. These CellMek devices include Cassette E. Class II

Reason: Automated pipetting, diluting and specimen processing workstations for flow cytometric analysis device instructions for use list incorrect dead volumes: Cassette Type/List volume/correct volume, B/750/1582 microliters, and E/1300/2093 microliters. Device software does not rock Cassette E, used with 15mmX92mm Sarstedt tubes. May lead to incorrect diagnosis or error in patient management/treatment.

Beckman Coulter, Inc. 20250908 Ongoing
Distributed: Worldwide - US Nationwide distribution in the states of AL, AR, FL, IL, IN, MA, ME, MI, MN, MO, NY, OR, TN, UT, WA and the countries Australia, Austria, Belgium, Brazil, Canada, China, France, Germany, Greece, Hong Kong, Israel, Italy, Japan, Korea, Republic of, Mexico, Morocco, Netherlands, Poland, Portugal, Puerto Rico, South Africa, Spain, Switzerland, United Kingdom of Great Britain and Northern Ireland.
MST ArcDUO 9mm, REF: ARC-0002, single-use, sterile ophthalmic knife, used with Suction Set, Part: 48-1000-01 Class II

Reason: An ophthalmic knife has a suction set (not direct patient-contacting), which contains springs contaminated with an unidentified residue that may potentially cause eye irritation

MicroSurgical Technology Inc 20250820 Ongoing
Distributed: US Nationwide distribution in the state of GA.
Page 300 of 4,030 | Showing 10 recalls