Reason: 3.5mmx38mm Locking Cortical Screw, implants are being recalled since an investigation identified that a 3.5mmx28mm Cortical Locking Screw is labeled as a 3.5mmx38mm Cortical Locking Screw.
Distributed: US Distribution including states of: AZ, CA, GA, IL, KY, MI, NC, NH, NY, OH, PA, SD, TX, UT, and VA.Reason: Current directions for use for the MCA cutting burs (item 18-0001) do not provide enough details regarding the intended use specifically for the MCA burrs.
Distributed: Worldwide Distribution - USA (nationwide) and Internationally to Great Britain, Australia, Switzerland, Sweden, France, Japan, Spain, Italy, Canada, and Netherlands.Reason: After a test in which a low SpO2 (yellow) medium grade alarm initiated in neo-natal mode and was subsequently paused, the high grade life threatening SpO2 alarm (red) did not activate when the SpO2 values were decreased to reach the red alarm limit.
Distributed: US Distribution including the states of: MA, NH, IN, CA, TX, NY, OK, and IL.Reason: RADIOMETER became aware that the regarded lot pO2 units 942-042R0971 were produced with inner solution for pCO2 membrane units. This solution is a salt solution similar to the pO2 inner solution, but also contains glycerol which can be reduced at the cathode causing a suddenly rising zero current, causing the membrane unit to fail the following Cal2 calibration.
Distributed: Worldwide Distribution - US (nationwide) including states of: CO, CT, GA, MA, MO & MS and country of: Canada.Reason: Extractor Pro XL Retrieval Balloon Catheters may have the incorrect skive hole location or balloon size
Distributed: Worldwide Distribution - USA (Nationwide Distribution and Puerto Rico) and Internationally.Reason: Extractor Pro XL Retrieval Balloon Catheters may have the incorrect skive hole location or balloon size
Distributed: Worldwide Distribution - USA (Nationwide Distribution and Puerto Rico) and Internationally.Reason: Extractor Pro XL Retrieval Balloon Catheters may have the incorrect skive hole location or balloon size
Distributed: Worldwide Distribution - USA (Nationwide Distribution and Puerto Rico) and Internationally.Reason: KLTD214 airways found inside KLTSD414 packages. The KLTSD414 airway has a lumen for use of a gastric suction tube; the KLTD214 airway does not include a lumen for a gastric suction tube.
Distributed: Distributed in the states of CA, NYReason: During a recent review of documentation Anspach determined that the current directions for use for the MCA cutting burrs and MCA Micro Curved Attachment do not provide clear details regarding the intended use specifically for the MCA burrs. The MCA burrs are intended for use in delicate bone in otologic procedures such as cochleostomy. The use of the device in dense bone removal may result in cu
Distributed: Worldwide Distribution - USA (nationwide) and Internationally to Canada, Netherlands, Great Britain, France, Sweeden, Italy, Spain, Japan, South Africa, Australia, Switzerland,Reason: ICU Medical is recalling certain lots of the NanoClave Needlefree Connector product line because of a small percentage of devices that may leak.
Distributed: Worldwide Distribution - USA including UT, TX, GA, WI, VT, NH, AL, OH, TN, IL, CA, KY,HI, NC, and Internationally to CA, BE, IN, KW, and AU.