ProPlan CMF Guide(s) Model(s) REF SD900.008 Description: Single Use Only : Patient-Specific Guide, Orthognathic, Final Single Use Only Rx only. Used as surgical tools to transfer a pre-operative plan to surgery. . Class II

Reason: Patient Specific Guide contained the incorrect case report. The case report contains patient specific surgical plan information.

Materialise USA LLC 20131108 Terminated
Distributed: Distributed in Canada.
ProPlan CMF Guide(s) Model(s) REF SD900.008 Description: Single Use Only : Patient-Specific Guide, Orthognathic, Intermediate Single Use Only Rx only. Used as surgical tools to transfer a pre-operative plan to surgery. Class II

Reason: Patient Specific Guide contained the incorrect case report. The case report contains patient specific surgical plan information.

Materialise USA LLC 20131108 Terminated
Distributed: Distributed in Canada.
Indus Invue Screws: IM71013-XX: Indus Screw04.0mm SelfDrilling. Used to secure the Invue Anterior Cervical Plate in position. Class II

Reason: Mismarked and unmarked screws

SpineFrontier, Inc. 20131120 Terminated
Distributed: Nationwide Distribution- including DC and the states of OH, TX, KS, MA, IN, CO, NY, AL, and MI.
Indus Invue Screws: IM71016-XX: 04.5mm, SelfTapping. Used to secure the Invue Anterior Cervical Plate in position. Class II

Reason: Mismarked and unmarked screws

SpineFrontier, Inc. 20131120 Terminated
Distributed: Nationwide Distribution- including DC and the states of OH, TX, KS, MA, IN, CO, NY, AL, and MI.
Indus Invue Screws: lM71059-XX: Indus Screw 04.2mm SelfDrilling. Used to secure the Invue Anterior Cervical Plate in position. Class II

Reason: Mismarked and unmarked screws

SpineFrontier, Inc. 20131120 Terminated
Distributed: Nationwide Distribution- including DC and the states of OH, TX, KS, MA, IN, CO, NY, AL, and MI.
Indus Invue Screws: IM71058-XX: 04.2mm, SelfTapping, Tapered. Used to secure the Invue Anterior Cervical Plate in position. Class II

Reason: Mismarked and unmarked screws

SpineFrontier, Inc. 20131120 Terminated
Distributed: Nationwide Distribution- including DC and the states of OH, TX, KS, MA, IN, CO, NY, AL, and MI.
Captia Syphilis-G Test Kit Product Usage: This is an enzyme immunoassay for the qualitative detection of IgG antibodies to T. pallidum in serum specimens, to be used in conjunction with non-treponemal testing to provide serological evidence of infection with T. pallidum ( the agent of syphilis). It is also intended for testing of serum or plasma specimens to screen blood and/or plasma donors to exclude a history of syphilis. Class II

Reason: Trinity Biotech recalled Trinity Biotech Captia Syphilis IgG kits due to false negative results.

Clark Laboratories, Inc. (dba,Trinity Biotech USA) 20130827 Terminated
Distributed: USA Nationwide Distribution in the state of WA
Instrument Manager driver : Driver sysu100i that connects to the Sysmex UF-100 analyzer Software all versions prior to( v7.00.0006 and v8.00.0005): v7.00.0001, v7.00.0002, v7.00.0003, v7.00.0004, v7.00.0005, v8 .00.0001, v8.00.0002, v8.00.0003, and v8 .00.0004 Class II

Reason: When connected to the Sysmex UF-100, the Instrument Manager driver sysu100i driver software versions 7.00.0001, 7.00.0002, 7.00.0003, 7.00.0004, 7.00.0005, 8.00.0001, 8.00.0002, 8.00.0003, and 8.00.0004, and is configured with option "Strip Zeros from Result" set to "Yes" may result in sample error

Data Innovations, Inc. 20131106 Terminated
Distributed: Nationwide Canada and Britain
Philips HeartStart MRx Monitor/Defibrillator with CO2/EtCO2 Measurement The HeartStart MRx is for use for the termination of ventricular tachycardia and ventricular fibrillation. The device is for use by qualified medical personnel trained in the operation of the device and qualified by training in basic life support, advanced cardiac support, or defibrillation. It must be used by or on the order of a physician. The HeartStart MRx EtCO2 Option monitors carbon dioxide (CO2) and measures end-tidal carbon dioxide (EtCO2). The option provides an EtCO2 value and a CO2 waveform on the devices display. Class II

Reason: MRx defibrillator displays a -?- for EtCO2 and does not display EtCO2 values when patient CO2 level falls below 7.6 mmHg

Philips Medical Systems, Inc. 20131210 Terminated
Distributed: US Nationwide and OUS.
IMMULITE/IMMULITE 1000 Systems FOL Folic Acid, REF/Catalog Number LKFO1 (100 tests), Siemens Material Number (SMN) 10380902, IVD; for in vitro diagnostic use with the IMMULITE and IMMULITE 1000 Analyzers --- Siemens Healthcare Diagnostics Products Ltd. An IVD for the quantitative measurement of folic acid in serum, heparinized plasma or ascorbic acid-treated whole blood, as an aid in clinical diagnosis and treatment of anemia. Class II

Reason: potential for an accelerated decline in counts per second (CPS) for three IMMULITE/IMMULITE 1000 Folic Acid kit lots. This may lead to a failed adjustment before the labeled expiration date is reached.

Siemens Healthcare Diagnostics 20131106 Terminated
Distributed: Worldwide Distribution - USA (nationwide) including Puerto Rico and the countries of Argentina, Bosnia-Herzegovina, Brazil, Bulgaria, Canada, Chile, China, Colombia, Costa Rica, Cyprus, Denmark, Dominican Republic, Estonia, France, Germany, Great Britain, Greece, Guatemala, Hungary, India, Italy, Latvia, Mexico, Netherlands, Panama, Paraguay, Poland, Portugal, Qatar, Romania, Russian Federation, Saudi Arabia, Serbia, Singapore, Slovakia, South Africa, Spain, Tunisia, United Arab Emirates, Uzbekistan and Venezuela.
Page 3,672 of 4,030 | Showing 10 recalls